Distribution system analysis, across every utility.
FacilityConnect rolls capacity up through the entire distribution network — electrical, process gas, CHW, exhaust, and beyond. The model surfaces the bottleneck upstream capacity that actually caps each branch, the limiting factors that drove the headroom number, and the correction factors applied at every level of the network.
B2-BP-A1-1
9 POCs
Limit
80 kva
DF 0.8
Peak 6.05 kva · Aug 1, 26
Bottleneck
B2-BP-A1-1
41%
used · Aug 1, 26
Demand
Upstream
B2-DP-208-A3
| Component | Size | Poles | Order | X | Y | Z | Assigned to |
|---|---|---|---|---|---|---|---|
| 1 | 63 | 1 | 1 | 5000 | 15000 | 0 | Not connected |
| 2 | 63 | 1 | 2 | 5000 | 15000 | 0 | Not connected |
| 3 | 63 | 1 | 3 | 5000 | 15000 | 0 | Not connected |
| 4 | 63 | 1 | 4 | 5000 | 15000 | 0 | T01-FabChiller · P04 7.566 kva |
| 5 | 63 | 1 | 5 | 5000 | 15000 | 0 | T01-FabChiller · P04 7.566 kva |
| 6 | 63 | 1 | 6 | 5000 | 15000 | 0 | T01-FabChiller · P04 7.566 kva |
| 7 | 63 | 1 | 7 | 5000 | 15000 | 0 | Not connected |
| 8 | 63 | 1 | 8 | 5000 | 15000 | 0 | Not connected |
| 9 | 63 | 1 | 9 | 5000 | 15000 | 0 | Not connected |
B2-DP-208-A1
13 POCs
Limit
150 kva
DF 0.64
Peak 28.69 kva · Aug 29, 26
Bottleneck
B2-DP-208-A1
37%
used · Aug 29, 26
Demand
Upstream
B2-DP-480-A
| Component | Size | Poles | Order | X | Y | Z | Assigned to |
|---|---|---|---|---|---|---|---|
| CKT1 | 250 | 3 | 1 | 30000 | 10000 | 0 | Not connected |
| CKT2 | 250 | 3 | 2 | 30000 | 10000 | 0 | B2-BP-A1-2 · BUS |
| CKT3 | 250 | 3 | 3 | 30000 | 10000 | 0 | T01-FabChiller · P101 4.323 kva |
| CKT4 | 250 | 3 | 4 | 30000 | 10000 | 0 | Not connected |
| CKT5 | 250 | 3 | 5 | 30000 | 10000 | 0 | Not connected |
| CKT6 | 250 | 3 | 6 | 30000 | 10000 | 0 | T01-FabChiller · P03 16.212 kva |
| CKT7 | 250 | 3 | 7 | 30000 | 10000 | 0 | Not connected |
| CKT8 | 250 | 3 | 8 | 30000 | 10000 | 0 | Not connected |
| CKT9 | 630 | 3 | 9 | 30000 | 10000 | 0 | T02-HVAC-RTU · P02 18.01 kva |
| CKT10 | 630 | 3 | 10 | 30000 | 10000 | 0 | T03-Spectrometer · P01 5.205 kva |
B2-DP-208-A2
11 POCs
Limit
150 kva
DF 0.7
Peak 84.20 kva · Sep 12, 26
Bottleneck
B2-DP-208-A2
78%
used · Sep 12, 26
Demand
Upstream
B2-DP-480-A
B2-BP-A1-2
7 POCs
Limit
80 kva
DF 0.8
Peak 19.20 kva · Jul 18, 26
Bottleneck
B2-DP-208-A1
24%
used · Jul 18, 26
Demand
Upstream
B2-DP-208-A1
B2-DP-208-A3
15 POCs
Limit
225 kva
DF 0.75
Peak 137.40 kva · Oct 4, 26
Bottleneck
B2-DP-480-A
87%
used · Oct 4, 26
Demand
Upstream
B2-DP-480-A
B2-BP-A1-3
5 POCs
Limit
80 kva
DF 0.8
Peak 12.80 kva · Jul 22, 26
Bottleneck
B2-DP-208-A1
16%
used · Jul 22, 26
Demand
Upstream
B2-DP-208-A1
Four inputs. One live distribution model.
The capacity rollup is only as accurate as what feeds it. FacilityConnect ingests tool demand, existing utility infrastructure, fab geometry, and your design intent — then keeps them in sync.
Import your tool utility matrix
Bring in the demand side of every tool — kVA, scfm, gpm, exhaust cfm — via spreadsheet import from your tool master list, with live progress on big files. Every demand value lives on a revisioned asset with a full audit trail.
Import your current utilities
Bring in the supply side: existing electrical panels, gas headers, CHW loops, exhaust risers and their as-built limits, demand factors, and upstream parents. The distribution tree builds itself, ready for capacity rollup.
Detail your fab layouts
Lay out buildings, levels, and grid lines so every demand and every supply point lives at a real coordinate. Distances and location-aware rollups run from this geometry, per scenario.
Assign — by hand or by Optimizer
Wire loads to supplies with rule-assisted assignment and live headroom signals — or hand the whole puzzle to the Optimizer, available today as a service, which proposes the balanced network into a scenario for your team to review. Issued revisions file automatically into Autodesk Construction Cloud.